Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Respir Care ; 69(4): 449-462, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538014

RESUMO

BACKGROUND: In recent years, mechanical power (MP) has emerged as an important concept that can significantly impact outcomes from mechanical ventilation. Several individual components of ventilatory support such as tidal volume (VT), breathing frequency, and PEEP have been shown to contribute to the extent of MP delivered from a mechanical ventilator to patients in respiratory distress/failure. The aim of this study was to identify which common individual setting of mechanical ventilation is more efficient in maintaining safe and protective levels of MP using different modes of ventilation in simulated subjects with ARDS. METHODS: We used an interactive mathematical model of ventilator output during volume control ventilation (VCV) with either constant inspiratory flow (VCV-CF) or descending ramp inspiratory flow, as well as pressure control ventilation (PCV). MP values were determined for simulated subjects with mild, moderate, and severe ARDS; and whenever MP > 17 J/min, VT, breathing frequency, or PEEP was manipulated independently to bring back MP to ≤ 17 J/min. Finally, the optimum VT-breathing frequency combinations for MP = 17 J/min were determined with all 3 modes of ventilation. RESULTS: VCV-CF always resulted in the lowest MPs while PCV resulted in highest MPs. Reductions in VT were the most efficient for maintaining safer and protective MP. At targeted MPs of 17 J/min and maximized minute ventilation, the optimum VT-breathing frequency combinations were 250-350 mL for VT and 32-35 breaths/min for breathing frequency in mild ARDS, 200-350 mL for VT and 34-40 breaths/min for breathing frequency in moderate ARDS, and 200-300 mL for VT and 37-45 breaths/min for breathing frequency for severe ARDS. CONCLUSIONS: VCV-CF resulted in the lowest MP. VT was the most efficient for maintaining safe and protective MP in a mathematical simulation of subjects with ARDS. In the context of maintaining low and safe MPs, ventilatory strategies with lower-than-normal VT and higher-than-normal breathing frequency will need to be implemented in patients with ARDS.


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/métodos , Ventiladores Mecânicos , Pulmão , Volume de Ventilação Pulmonar , Síndrome do Desconforto Respiratório/terapia
3.
Eur J Emerg Med ; 21(3): 230-2, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23022772

RESUMO

Noninvasive positive pressure ventilation is increasingly being used in emergency departments across Europe and North America. To our knowledge, no similar data are available from other countries. The aim of this study is to describe the current use of noninvasive positive pressure ventilation in the emergency departments of Lebanese hospitals. A structured and validated questionnaire was sent to all emergency departments in Lebanon. In Lebanon, 48.4% of emergency departments use noninvasive positive pressure ventilation. It is mostly used for patients with chronic obstructive pulmonary diseases and cardiogenic pulmonary edema. Bilevel and continuous positive airway pressures are the two most widely used modalities for noninvasive positive pressure ventilation. Face mask is the most used patient interface. The use of uniform protocols and training is lacking. Noninvasive positive pressure ventilation in Lebanese emergency departments is underused, with significant potential for improvements in its current practice.


Assuntos
Serviço Hospitalar de Emergência , Hospitais Privados/estatística & dados numéricos , Hospitais Públicos/estatística & dados numéricos , Ventilação não Invasiva/estatística & dados numéricos , Respiração com Pressão Positiva/estatística & dados numéricos , Estudos Transversais , Tratamento de Emergência/métodos , Feminino , Necessidades e Demandas de Serviços de Saúde , Humanos , Líbano , Masculino , Ventilação não Invasiva/tendências , Respiração com Pressão Positiva/tendências , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...